ACEY-PCT501-512 pouch battery formation and grading system can set the working steps and accurately measure the key parameters of the battery such as voltage, current and capacity through cyclic charge and discharge tests.
Brand:
ACEYItem No.:
ACEY-PCT501-512Compliance:
CE CertifiedWarranty:
One-year warranty with lifetime supportOrder(Moq):
1 setPayment:
T/TProduct Origin:
ChinaLead Time:
7-35 days5V 1A 512-Channel Lithium Ion Cell Tester Pouch Battery Formation And Grading System
	
 
Description
	The device is connected to a computer for control, sending commands and collecting data. A keyboard allows for manual operation and displays parameters and status. The constant current plate, controlled by the CPU, maintains constant current and voltage. During battery charging and discharging, the constant current plate controls and monitors the battery's charge and discharge. The charging process utilizes a seamless CCCV transition, eliminating any voltage or current surges. This effectively prevents heat concentration from peak currents, which can lead to tab powder loss or micro-shorting, resulting in islanding or overcharge.
 
	
 
System Features
	
 
Specification
	 
	
		
			
				 
			
					Working power 
				 
				
					Three-phase five-wire system AC380V±10%, 50HZ 
				 
			
				 
			
					Work environment 
				 
				
					Temperature 0-40 degrees, relative humidity ≤80% 
				 
			
				 
			
					Heat-dissipating method 
				 
				
					Take in the wind naturally and exhaust it upward 
				 
			
				 
			
					Channel Parameter 
				 
			
				 
			
					Voltage measuring range 
				 
				
					0-5V, 1MV resolution 
				 
			
				 
			
					Battery voltage range 
				 
				
					Charge 0-4.5V: Discharge 4.5-2V 
				 
			
				 
			
					Constant voltage range 
				 
				
					2.5V-4.5V 
				 
			
				 
			
					voltage accuracy 
				 
				
					±(1‰ reading +1‰ full) 
				 
			
				 
			
					Current accuracy 
				 
				
					±(1‰ reading +1‰ full) 
				 
			
				 
			
					Software Function 
				 
			
				 
			
					Control mode 
				 
				
					Computer connection equipment work, FCL control 
				 
			
				 
			
					Communication mode 
				 
				
					RS485 baud rate 57,600 
				 
			
				 
			
					Process set 
				 
				
					A maximum of 32 work steps and 256 cycles are se 
				 
			
				 
			
					Charging mode 
				 
				
					Constant current, constant pressure 
				 
			
				 
			
					Charging cutoff condition 
				 
				
					Voltage, current, time, capacity 
				 
			
				 
			
					Discharge 
				 
				
					constant current 
				 
			
				 
			
					Discharge cut-off condition 
				 
				
					Voltage, time, capacity 
				 
			
				 
			
					Defensive function 
				 
				
					Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity, etc 
				 
			
				 
			
					Time range 
				 
				
					Set it anywhere from 0 to 30,000 minutes 
				 
			
				 
			
					Time accuracy 
				 
				
					≤±1‰ 
				 
			
				 
			
					Sampling inspection period 
				 
				
					≤8S 
				 
			
				 
			
					Minimum frequency of data recording 
				 
				
					≤8S 
				 
			
				 
			
					Battery sorting 
				 
				
					By capacity, time, discharge platform, etc 
				 
			
				 
		
	
					Data processing 
				 
				
					 Data, graphs, and loop diagrams 
				 
			
 