ACEY-PCT501-512 pouch battery formation and grading system can set the working steps and accurately measure the key parameters of the battery such as voltage, current and capacity through cyclic charge and discharge tests.
Brand:
ACEYItem No.:
ACEY-PCT501-512Compliance:
CE CertifiedWarranty:
One-year warranty with lifetime supportOrder(Moq):
1 setPayment:
T/TProduct Origin:
ChinaLead Time:
7-35 days5V 1A 512-Channel Lithium Ion Cell Tester Pouch Battery Formation And Grading System
Description
The device is connected to a computer for control, sending commands and collecting data. A keyboard allows for manual operation and displays parameters and status. The constant current plate, controlled by the CPU, maintains constant current and voltage. During battery charging and discharging, the constant current plate controls and monitors the battery's charge and discharge. The charging process utilizes a seamless CCCV transition, eliminating any voltage or current surges. This effectively prevents heat concentration from peak currents, which can lead to tab powder loss or micro-shorting, resulting in islanding or overcharge.
System Features
Specification
Working power
Three-phase five-wire system AC380V±10%, 50HZ
Work environment
Temperature 0-40 degrees, relative humidity ≤80%
Heat-dissipating method
Take in the wind naturally and exhaust it upward
Channel Parameter
Voltage measuring range
0-5V, 1MV resolution
Battery voltage range
Charge 0-4.5V: Discharge 4.5-2V
Constant voltage range
2.5V-4.5V
voltage accuracy
±(1‰ reading +1‰ full)
Current accuracy
±(1‰ reading +1‰ full)
Software Function
Control mode
Computer connection equipment work, FCL control
Communication mode
RS485 baud rate 57,600
Process set
A maximum of 32 work steps and 256 cycles are se
Charging mode
Constant current, constant pressure
Charging cutoff condition
Voltage, current, time, capacity
Discharge
constant current
Discharge cut-off condition
Voltage, time, capacity
Defensive function
Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity, etc
Time range
Set it anywhere from 0 to 30,000 minutes
Time accuracy
≤±1‰
Sampling inspection period
≤8S
Minimum frequency of data recording
≤8S
Battery sorting
By capacity, time, discharge platform, etc
Data processing
Data, graphs, and loop diagrams
Product Display