ACEY-HRCDS-5V200A-20CH lithium cell testing machine is professionally used to test battery cycle life and performance. It supports multiple charge and discharge modes such as constant current, constant voltage, and pulse. It has high-precision voltage/current control and multi-channel parallel testing capabilities. It can simulate real working conditions and monitor fixture contact impedance. It is widely used in R&D, production, and quality inspection.
Brand:
ACEYItem No.:
ACEY-HRCDS-5V200A-20CHCompliance:
CE CertifiedWarranty:
One-year warranty with lifetime supportOrder(Moq):
1 SetPayment:
T/TProduct Origin:
ChinaLead Time:
7-35 days5V 200A 20CH Energy-feedback Lithium Ion Battery Charge Discharge Tester
Application
ACEY-HRCDS-5V200A-20CH Lithium cell testing machine is mainly used for cycle life testing and quality control of li-ion battery, lead-acid battery, Ni-Cd battery, NiMH battery and so on in production line or in lab.Function
Working Environment
Parameters
No. | Item | ACEY-HRCDS-5V200A | ||
1 | Main channels | 2CH/ module | ||
2 | Channel working mode | Completely independent. | ||
3 | Main channel working mode | Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV. | ||
Discharge: CD, CP, CR, DCCV. | ||||
Still, Pulse test, Working Condition test, DCIR test. | ||||
Main channel test cutoff condition | Time, total voltage, total current, capacity, -ΔV, Vcell, RSOC, etc. | |||
4 | Main channel Voltage | Single channel test range | 0V-5V | |
Min. discharge voltage | 1V | |||
Accuracy | ±0.05%FS | |||
Resolution | 0.1mV | |||
Main channel Current | Single channel test range | ±200A | ||
Min. output current | 200mA | |||
Accuracy | ±0.05%FS | |||
Resolution | 1mA | |||
Current start response time | <10ms(10%FS~90%FS) | |||
Time | Resolution | 10mS | ||
Auxiliary temperature (Optional) | Range | ﹣20℃~100℃ | ||
Accuracy | ±1℃(0℃~70℃) | |||
Resolution | 0.1℃ | |||
Power | Output power | Single channel continuous working power 1000W | ||
Stability | ±0.1%FS | |||
5 | Communication | LAN | ||
6 | Control program | Support data protection when power off, continue testing caused of power cutoff or manually stop and revise step parameter online. | ||
Users can set protection condition, include minimum voltage, maximum voltage, minimum current, maximum current, etc. | ||||
Users can set auxiliary channel protection condition, including minimum voltage, maximum voltage, maximum temperature, minimum temperature. | ||||
Cycle time | Max. 9999 | |||
Programmable step | Max. 9999 | |||
Nested loop | Max. 10 layers | |||
Step time range | No limit, support h, min, s | |||
Data record | Time≥10ms,Voltage≥0.05%FS,Current≥0.05%FS | |||
Program feature | Each step has one or multiple exit | |||
7 | Data display | Cycle list | Circulation number. Charge/discharge capacity, efficiency, power and average voltage, etc. | |
Process list | Process number, working mode, process time, capacity, power, DIR, medium voltage, cut-off voltage, cut-off current, etc. | |||
Detail list | Record number, system time, cumulative time, voltage, current, energy, power, cell temperature, etc. | |||
8 | Data export | Data can be exported as EXCEL, TXT or diagram. Provide charge discharge efficiency, charge discharge curve, voltage, capacity, current-time characteristic curves, etc. | ||
9 | Data saving | Save as files | ||
10 | Curves type | X-coordinate: total time, charge discharge capacity, cycle time, voltage, current, capacity. | ||
Y-coordinate: total voltage, current, capacity, power, cell temperature(Optional), end of charge and discharge capacity, etc. | ||||
11 | Software protection | Power off data protection, power resume continue testing, OVP, ODP, OCP, UCP, OTP, capacity protection, abnormal voltage trend protection, abnormal current trend protection, abnormal current fluctuation protection, abnormal voltage fluctuation protection, abnormal charging voltage increase rate protection, abnormal discharge current decrease rate protection. | ||
Hardware protection | Power off, open circuit and short circuit protection. Reverse or wrong connection protection, OCP, OVP, OTP, fixture contact abnormal protection. | |||
Warning function | Switch off automatically under emergency, shutdown when power off, load connect and disconnect automatically. | |||
12 | Barcode scan | Support barcode start and binding test data, classify batteries rapidly and accurately. Support detailed battery database management functions, connect battery information with testing data base, which is easy for management of data base system. | ||
13 | Sampling terminals | Four-polar sampling. Copper nose or other fixture. | ||
14 | Energy consumption | Discharge power feedback to grid | ||
15 | Cooling method | Forced Fan-cooled | ||
Noise | Less than 70dB | |||
IP grade | IP20 | |||
16 | Repair | Modularized structure. Can be replaced or repair with spare parts. |
Equipment Specification
Cabinet size | 600*800*1980mm |
Weight | ≤300KG |
Channels number | 20CH |
Remarks :The above picture is for reference only, subject to the kind! |
Product Display