ACEY-PCT501-512 pouch battery capacity grading machine is used for formation, capacity grading, and performance parameter testing of polymer lithium batteries.
Brand:
ACEYItem No.:
ACEY-PCT501-512Compliance:
CE CertifiedWarranty:
One-year warranty with lifetime supportOrder(Moq):
1 setPayment:
T/TProduct Origin:
ChinaLead Time:
7-35 days5V 1A Pouch Battery Charge Discharge Cell Capacity Grading Machine
Description
ACEY-PCT501-512 pouch cell capacity grading machine adopts a master-slave control structure comprised of a computer and a microcontroller, featuring advanced design, stable performance, ease of operation, and high testing efficiency. The computer communicates with the equipment, sending commands and acquiring data, while the keyboard is used for manual operation, displaying parameters, and monitoring status. The constant current board is controlled by the CPU, achieving constant current and constant voltage functions. With its excellent cost-performance ratio, this system is an indispensable testing and production tool for lithium battery manufacturers, capacity grading plants, and research institutions.
System Features
Specification
Structure Of Equipment
Number of device channels
512 Channels
Size (width * depth * height) cm
160*55*184
Clamp form
Cylindrical four-wire fixture
Color of device
Dark grey
Clamp center distance
40mm/35mm
Support battery height
Adjustable within 10-100mm range
Working power
Three-phase five-wire system ac380v±10%, 50hz
Working power dissipation
≤27kw
Work environment
Temperature 0-40 ℃, relative humidity ≤80%
Heat-dissipating method
Natural wind intake and upward exhaust
Channel Parameter
Voltage testing range
0-5V, 1MV resolution
Battery voltage range
Charge 0-4.5V: Discharge 4.5-2V
Constant voltage range
2.5V-4.5V
Voltage accuracy
±(1‰ reading +1‰ full)
Current range
60mA-1A, Reslution: 1mA
Current accuracy
±(1‰ reading +1‰ full)
Control mode
Computer connection equipment work, Whole
Machine Control
Software Function
Communication mode
Rs485, baud rate 57,600
Process set
Maximum 32 work steps and 256 cycles
Charging mode
Constant current, constant voltage
Charging cutoff condition
Voltage, current, time, capacity
Discharge
Constant current
Discharge cut-off condition
Voltage, time, capacity
Protection function
Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity, etc
Time range
0 - 30,000 minutes
Time accuracy
≤±1‰
Sampling inspection period
≤8s
Minimum data recording frequency
≤8s
Battery grading
By capacity, time, discharge platform, etc
Data processing
Data, graphs, and loop diagrams
Product Display