ACEY-BCT5100-48P lithium ion battery cell testing machine is used to test the capacity, voltage and other parameters of power lithium battery, and to grade them according to performance indicators to ensure the consistency of the battery pack.
Brand:
ACEYItem No.:
ACEY-BCT5100-48PCompliance:
CE CertifiedWarranty:
One-year warranty with lifetime supportOrder(Moq):
1 SetPayment:
T/TProduct Origin:
ChinaLead Time:
7-35 days5V 100A 48CHS Regenerative Lithium-ion Battery Cell Capacity Testing Machine
Product Features
ACEY-BCT5100-48P prismatic lithium battery cell testing machine is a high-precision battery testing system featuring independent 2-channel programmable CC/CV sources and a four-wire interface for maximum accuracy. Controlled by an STM32 MCU, it offers a user-friendly graphical interface for real-time monitoring, data logging, and sorting, with a specialized FET-based design optimized for low-voltage discharge (e.g., LiFePO4). The system ensures high reliability through its modular architecture, power-off memory, and comprehensive abnormality protection, making it a robust and easy-to-maintain solution for professional battery capacity grading.Equipment Workflow
Compatible Battery
Length
65-300mm
Thickness
15-75mm
Height
70-320mm
Tab spacing
50-250mm
Specification
|
Equipment structure |
|
|
Number of Device Channels |
The whole machine has 48 channels |
|
Exterior dimension |
Width 1009mm × Length 800mm × Height 1843mm |
|
Chassis Color |
Standard gray black (customizable)) |
|
Fixture form |
Power battery flat head clamp |
|
Clamp spacing |
84mm |
|
Channel Control Mode |
Each battery has a completely independent constant current constant voltage source, stable and no impact. Realizable start |
|
move, stop, pause, continue and protect |
|
|
Each channel has an independent constant voltage, constant current hardware control circuit |
|
|
Each channel charging current, discharge current accuracy can be automatically calibrated by software |
|
|
Working power supply |
Three-phase 5 wire system AC380V ± 10%,50HZ |
|
power factor |
≥ 0.99 |
|
AC current distortion rate |
≤ 2% |
|
Power Department Efficiency Index |
Charging ≥ 80%, discharging ≥ 75% |
|
Working power consumption |
≤ 29KW |
|
equipment failure rate |
<1% |
|
Working environment |
Temperature -10~40, relative humidity 80% |
|
Heat dissipation mode |
Natural air intake, upward exhaust |
|
smoke alarm |
Optional |
|
Power component protection function |
1. Grid voltage overrun protection |
|
2. Power grid frequency overrun protection |
|
|
Channel Parameters |
|
|
Voltage measurement range |
DC 0~5V |
|
Battery voltage range |
Charge DC 0~4.5V; Discharge DC 4.5~1.5V |
|
Constant voltage range |
DC 2~4.5V |
|
Voltage accuracy |
±(0.5 reading ‰ +0.5 ‰ full) |
|
Voltage control resolution |
0.1mV |
|
Voltage sampling resolution |
0.1mV |
|
voltage stability |
≤(± 1mV) |
|
Current range |
Charging DC 200mA ~ 100A; Discharging DC 200mA ~ 100A |
|
Current accuracy |
±(0.5 reading ‰ +0.5 ‰ full) |
|
Current control resolution |
1mA |
|
Current Sampling Resolution |
0.1mA |
|
Current stability |
≤(± 1mA) |
|
Current rise time (90% load) |
≤ 50MS |
|
Channel startup time (90% load) |
≤ 50MS |
|
Software function |
|
|
Control mode |
Computer-controlled equipment work, full cabinet control, with scanning system |
|
Communication mode |
485 serial port communication (baud rate 57600 )/ TCP communication |
|
Process Settings |
Up to 32 steps and 256 cycles can be set |
|
Charging mode |
Constant current, constant voltage, constant current and constant voltage |
|
Charging end conditions |
Voltage, current, time, capacity,-△V |
|
Discharge mode |
Constant current, constant power, constant resistance |
Product Details