ACEY-ZP13S001 is a 13S 30A 48V bms with balance and temperature protection function for 3.7V lithium ion battery packs.
Brand:
ACEYItem No.:
ACEY-ZP13S001Compliance:
CE CertifiedWarranty:
One Year warranty with lifetime supportPayment:
T/TProduct Origin:
ChinaLead Time:
7days13s 25a 48v Bms With Balance For 3.7V Lithium Ion Battery Pack
Product Introduction
ACEY-ZP13S001 is designed by Xiamen Acey New Energy Technology Co., Ltd., is the same-port protection plate for 13 battery packs of electric bicycles, electric motorcycles and other products. Suitable for different chemical properties of lithium cell, such as lithium ion, lithium polymer, lithium iron phosphate, etc.Protection plate with strong carrying capacity, continuous discharge current up to 25A.
● Section 13 Integrated protection scheme
● Blancing
● Various protection functions for charging and discharging
● Discharge overcurrent, short circuit protection functional processes of hardware
● Temperature protection function
● Very low static current consumption
● Drop line protection function
Electrical Characteristics
(The test needs to be carried out in a room with a temperature of 25±2°C and a relative humidity of 65 +/- 20 %)
Functions | Test items | specification | Unit | ||
Min. | Type | Max. | |||
Operating Voltage | voltage range | 36.4 | 55.25 | V | |
Operating current | recharging current | -- | -- | 6 | A |
Discharging current | -- | -- | 25 | A | |
Charging protection | Charger voltage (CC-CV) | 54.6 | V | ||
Over-charge protection voltage | 4.2 | 4.25 | 4.3 | V | |
Over-charge protection delay time | 500 | 1000 | 2000 | mS | |
Over-charge protection recovery voltage | 4.05 | 4.15 | 4.2 | V | |
Equalization function | Balanced turn-on voltage | 4.15 | 4.18 | 4.21 | V |
Equilibrium current | 20 | _ | 40 | mA | |
Discharge protection | Over-discharge protection voltage | 2.7 | 2.8 | 2.9 | V |
Over-discharge protection delay time | 1000 | 2000 | 3000 | mS | |
Over-discharge protection recovery voltage | 2.9 | 3 | 3.1 | V | |
Over-discharge protection recovery condition | Charge or disconnect the load | ||||
Overcurrent protection | Charging overcurrent protection value | 10 | 15 | 20 | A |
Overcurrent charge delay | 500 | 1000 | 1500 | mS | |
Charging release adjustment | Disconnect charger | ||||
Discharge overcurrent 1 protection current value | 65 | 75 | 85 | A | |
Discharge overcurrent 1 protection delay | 100 | 200 | 300 | mS | |
Discharge overcurrent protection recovery condition | Disconnect the load or charge | ||||
Short circuit protection | Short circuit protection current | 200 | 300 | A | |
Short circuit protection delay time | 100 | 300 | 500 | uS | |
Short circuit protection recovery | Disconnect the load or charge | ||||
Temperature protection | Charging high temperature protection | 46 | 50 | 54 | ℃ |
Charging high temperature protection release | 43 | 47 | 51 | ℃ | |
Charging low temperature protection | -15 | -10 | -5 | ℃ | |
Charging low temperature protection release | -10 | -5 | 0 | ℃ | |
Discharge high temperature protection | 65 | 70 | 75 | ℃ | |
Discharge high temperature protection release | 50 | 55 | 60 | ℃ | |
Internal resistance | Discharge loop internal resistance | / | 10 | 20 | mR |
Self-consuming | Operating mode | / | 40 | 70 | uA |
Operating temperature | Normal working range | -20 | 70 | ℃ | |
storage temperature | Humidity is lower than 90% | -40 | 85 | ℃ | |
Protection board size | length*Width*Height | (60±2)*(52±2)*(10±2) | mm | ||