100V 100A regenerative battery pack test system is mainly used for circle life testing and quality control of li-ion battery, lead-acid battery, Ni-Cd battery, NiMH battery and so on in production line or in lab.
Brand:
ACEYItem No.:
ACEY-HRCDS-100V100ACompliance:
CE CertifiedWarranty:
One Year warranty with lifetime supportOrder(Moq):
1 SetPayment:
T/TProduct Origin:
ChinaLead Time:
7days100V 100A Regenerative Battery Pack Charge DischargeTest System
Application and Function
100V 100A regenerative battery pack charge-discharge test system is mainly used for circle life testing and quality control of li-ion battery, lead-acid battery, Ni-Cd battery, NiMH battery and so on in production line or in lab.
Equipment configuration list
No.
Category
Product name
Product model
Quantity
Remarks
1
Test equipment
Charge and discharge test equipment
ACEY-HRCDS-100V100A
4CH
2
Cabinet
Charging and discharging equipment cabinet
/
1PCS
Default without power input line
3
Computer
Computer
Dell computer I5-10500 processor / 16G memory / 256G solid state + 1T hard disk / 3 network port
1PCS
Optional, including mouse, keyboard and 19 inch AOC displayer
4
Accessories
Charge discharge test line
/
4PCS
Each channel has a set of test lines with a length of 3.5meters.(including fixture)
5
Accessories
BMS power supply
12V/24V
2
Optional, 2 channels for each power supply
6
Accessories
Switch
TP-LINK TL-SF1008VE
1PCS
7
Accessories
Communication accessories
Communication line / Crystal head, etc.
Several
For communication
8
Accessories
USB Flash Drive
16G
1PCS
Contains Test software etc.
9
Accessories
File
/
1PCS
Test report, packing list, etc
Advantages
Working Environment and Technical Parameters
Parameters
No. | Item | ACEY-HRCDS-100V100A | ||
1 | Main channels | 1CH/ module | ||
2 | Output power | The maximum power of channel operation is 10kW; timeless | ||
3 | Output power stability | ±0.1%FS | ||
4 | Power quality at input side | Power factor | >99%(full load) | |
Total harmonic distortion rate | ≤5%(full load) | |||
5 | Energy consumption parameters | Standard sine wave feedback energy, high efficiency (optimal efficiency 90%%) | ||
6 | Main channel working mode | Charge: CC, CV, CCCV, no voltage or current impact when CC transfer to CV | ||
Discharge: CD, CP, CR | ||||
Still | ||||
Working condition test; Pulse test. | ||||
7 | Main channel Voltage | Single channel test range | 0.2V-100V, The intermediate value is continuously adjustable (wide test range, applicable to the test requirements of various battery modules) | |
Min. discharge voltage | 7V(Device port voltage) | |||
Accuracy | ±0.05%FS | |||
Resolution | 1mV | |||
Main channel Current | Single channel test range | ±100A | ||
Min. output current | 150mA | |||
Accuracy | ±0.05%FS | |||
Resolution | 1mA | |||
Current start response time | <5ms(10%~90%FS) | |||
Time | Resolution | 10ms | ||
Auxiliary voltage (Optional) | Range | DC: 0-5V | ||
Accuracy | ±0.05%FS | |||
Resolution | 1mV | |||
Auxiliary temperature (Optional) | Range | ﹣20℃~100℃ | ||
Accuracy | ±1℃(0℃~70℃) | |||
Resolution | 0.1℃ | |||
8 | Communication | LAN | ||
Battery BMS communication | Support CAN 2.0A, CAN 2.0B; RS485 communication | |||
Support DBC import, realize data reading with BMS CAN, and participate in process control |
Product Display