Language : English

English

$this->product_detail['product_name']

1000V 400A High Voltage Battery Cycler

ACEY-RCDS-1000V400A Battery cycler is used for module battery testing of large battery production lines such as electric vehicles/energy storage power stations.

  • Brand:

    ACEY
  • Item No.:

    ACEY-RCDS-1000V400A
  • Compliance:

    CE Certified
  • Warranty:

    One Year warranty with lifetime support
  • Order(Moq):

    1 Set
  • Payment:

    T/T
  • Product Origin:

    China
  • Lead Time:

    7days
  • Product Detail

500V/800V/1000V-300A/400A/600A High Voltage Battery Cycler



Application and Function

1000V 400A regenerative high voltage battery cycler is mainly used for circle life testing and quality control of li-ion battery, lead-acid battery, Ni-Cd battery, NiMH battery and so on in production line or in lab. 


Support battery circle life testing, capacity testing, charging characteristic testing, discharging characteristic testing, charge retention capability testing, charge and discharge efficiency testing, over charge or over discharge rate affordability testing. 


Equipment configuration list

 

No. Category Product name Product model Quantity Remarks
1 Test equipment Charge and discharge test equipment ACEY-RCDS-1000V400A-450KW-2CH 2CHS
2 Cabinet Charging and discharging equipment cabinet / 1PCS Default without power input line
3 Computer Computer Dell computer I5-10500 processor / 16G memory / 256G solid state + 1T hard disk / 3 network port 1PCS Optional, including mouse, keyboard and 19 inch AOC displayer
4 Accessories Charge discharge test line / 2PCS Each channel has a set of test lines with a length of 5meters.(including fixture)
5 Accessories BMS power supply 12V/24V 2 Optional
6 Accessories Switch TP-LINK TL-SF1008VE 1PCS
7 Accessories Communication accessories Communication line / Crystal head, etc. Several For communication
8 Accessories USB Flash Drive 16G 1PCS Contains Test software etc.
9 Accessories File / 1PCS Test report, packing list, etc.


Advantages

  • Power feedback to grid with direct current bus efficiency ≥90%: Both charging and discharging is energy-saving which saves a lot of electric power expenses and air-conditioner fees.
  • CCCV charge: CC charge transfer to CV charge smoothly, without any impact, which can avoid the micro-shot circuit due to high temperature of peak current impact or to avoid PCB protection or second protection action caused by over-charging.
  • Current and voltage sampling is of high stability and accuracy: this equipment applied 16bit bipolar ADC/DAC unit, to ensure voltage sampling high accuracy and long-term stability.
  • User management includes authority management, role management and user management. Managers can set management permissions for each function module of the software, and set multiple user IDs according to the operator's permission requirements.
  • DCIR: four DCIR test schemes are supported to meet different test requirements.
  • Voltage clamp function: when battery does protect action through charging process, voltage clamp to pre-set voltage can protect battery or PCB from damage.
  • The recording conditions can be set by sections in the test step, and the intelligent data management record can be implemented.
  • Each channel has a built-in CAN and RS485 communication module to support BMS CAN communication function: collect the total voltage, total current, single cell voltage, temperature and other data of BMS system in real time, and make synchronous comparison with CDS voltage and current data. When setting BMS voltage, current, temperature and other data to a certain condition, the main channel steps will stop or convert, and the specific reading information will be provided by the customer.
  • Support one click DBC import and manual customization of BMS protocol functions, and support sampling different BMS protocols for each channel.
  • It supports user-defined signal sets. Users can customize the setting name according to their own needs and data recording requirements. By adding "sub semaphore" as protection parameters, multiple protection parameters can be set through the operators "maximum value, minimum value, difference value, mean value, +, -,×,÷, and, or, exponential variance, sine and cosine "function and other numerical relations are calculated, and the obtained results can generate new judgment conditions.



Working Environment and Technical Parameters

  1. Power supply: AC 380V±20%, frequency: 50HZ±10%. 
  2. Maximum input power of the whole cabinet: 473.7 KW
  3. Working temperature: 0℃ - 45℃.
  4. Humidity: less than ≤ 95%R.H (non-condensing).
  5. No severe shake, no corrosive gases, no flammable or explosive gases around.
  6. Resolution: AD 16 bit.
  7. Cabinet size: 2200*1105*2000mm.

  8. Weight: ≤3000kg.


Parameters

No. Item ACEY-RCDS-1000V400A-450KW-2CH
1 Main channels 2CH/Rack
2 Output power The maximum power of single channel operation is 400KW;
Power 450KW (continuous power) when two channels operate at the same time
3 Output power stability ±0.1%FS
4 Power quality at input side Power factor 99%(full load)
Total harmonic distortion rate 3%(full load)
5 Output Voltage Ripple 0.3%F.S
6 Energy consumption parameters Standard sine wave feedback energy, high efficiency (optimal efficiency 95%)
7 Main channel working mode Charge: CC, CV, CCCV,  no voltage or current impact when CC transfer to CV
Discharge: CD, CP, CRDCCV
Still
Working condition test; Pulse test; DCIR
8 Main channel Voltage Single channel test range 2V-1000V, The intermediate value is continuously adjustable (wide test range, applicable to the test requirements of various battery modules)
Min. discharge voltage 15V
Accuracy ±0.05%FS
Resolution 20mV
Main channel Current Single channel test range ±400A
Min. output current 100mA
Accuracy ±0.05%FS
Resolution 10mA
Current start response time <10ms
Time Resolution 10ms
9 Communication LAN
Battery BMS communication Support CAN 2.0A, CAN 2.0B;
Support DBC import, realize data reading with BMS CAN, and participate in process control


Product Display

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related Products
Battery Pack Aging Machine 12 Channels 30V 10A Charging 20A Discharging Battery Pack Aging Tester

ACEY-BT3020-12 has the functions of constant current and constant voltage charging and constant current discharge. It can charge and discharge the battery and record the battery capacity.

Battery Pack Aging Testing Equipment Lithium Battery 6 Channels 30V 10A Charging 20A Discharging Aging Cabinet

ACEY-BT3020-6 is mainly used to test battery charging protection voltage, discharging protection voltage, capacity, etc.

Battery Charge And Discharge Aging Machine 70V Aging Cabinet Lithium Battery Pack 5A Charging 10A Discharging Aging Tester

ACEY-BT7010-12 is applied to the integrated charge discharge cycle test system of low string lithium battery pack cycle charge and discharge, battery pack function test and charge discharge data monitoring.

Battery Charge And Discharge Aging Test Machine 85V 10A Charge 20A Discharge Life Cycle Tester For Lithium Battery Pack

ACEY-BT8520-7 is mainly used for testing the charging and discharging cycle of finished lithium batteries.The equipment has four test steps: charging, discharging, shelving and cycling. By editing the corresponding step, the battery can be tested according to the set process.

Battery Charge And Discharge Aging Test Machine 7 Channels 100V 10A Charging 20A Discharging Battery Pack Aging Cabinet

ACEY-BT10020-7 is mainly used for testing the charging and discharging cycle of finished lithium batteries.The equipment has four test steps: charging, discharging, shelving and cycling. By editing the corresponding step, the battery can be tested according to the set process.

Lithium ion Battery Pack Charge Discharge System 100V 30A Battery Pack Life Cycle Tester

100V 30A battery life cycle tester mainly used for circle life testing and quality control of li-ion battery, lead-acid battery, Ni-Cd battery, NiMH battery and so on in production line or in lab.

Battery Charge Discharge Test Equipment 100V 100A Regenerative Battery Pack Test System

100V 100A regenerative battery pack test system is mainly used for circle life testing and quality control of li-ion battery, lead-acid battery, Ni-Cd battery, NiMH battery and so on in production line or in lab.

Battery Charge Discharge Test Equipment 200V 100A Battery Charge And Discharge Test System

Battery charge and discharge test system is to accelerate the aging process of the battery by simulating the charge and discharge cycle in the actual use scene, so as to evaluate the performance and life of the battery under actual use conditions more quickly.

Leave a message